NDI Monitor
Check for Interoperability
Run the testing application on a testing display connected to the PC
Run NDI Screen Capture.
Connect to that Screen Capture setting with Studio Monitor and confirm the frame rate and resolution. Shut the Studio Monitor application down
Connect the NDI monitor being tested to the Screen Capture source
Connect a previously tested PTZ camera to the network
Point the PTZ camera to the NDI monitor being tested
Connect the testing application to the PTZ cameraβs output
Run the test and record the results
Subtract the PTZβs previous results from the new metrics